RESEARCH ARTICLE
Year : 2015  |  Volume : 4  |  Issue : 1  |  Page : 82-100

A linear principal component regression and nonlinear neural network model for determination of indomethacin in plasma samples using UV-Vis spectroscopy and comparison with HPLC


1 Medical Biology Research Center, Kermanshah University of Medical Sciences, Kermanshah, Iran
2 Student Research Committee, Kermanshah University of Medical Sciences, Kermanshah, Iran
3 Pharmaceutical Sciences Research Center, Faculty of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran
4 Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Kermanshah, Iran

Correspondence Address:
Mohsen Shahlaei
Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Kermanshah
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

A sensitive and selective method using combination of two chemometrics methods, principal component Analysis (PCA) and artificial neural network (ANN), and UV-Visible spectroscopy has been developed for the determination of Indomethacin (IDM) in plasma samples. Initially the absorbance spectra were processed using PCA to noise reduction and data compression. The scores of these PCs were used as the inputs of ANN. The ANN trained by the back-propagation learning was employed to model the complex non-linear relationship between the PCs extracted from UV-Visible spectra of IDM and the absorbance values. Nonlinear method (PC-ANN) was better than the PCR method considerably in the goodness of fit and predictivity parameters and other criteria for evaluation of the proposed model. Optimal ANN model were as follows: Number of input PCs: 2, number of neurons in hidden layer: 3. The linear calibration range was 1×10-7 to 2.4×10-6 M, the detection limit were 0.21 × 10-7 M., The results have been compared with those obtained by the HPLC method.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed442    
    Printed51    
    Emailed0    
    PDF Downloaded86    
    Comments [Add]    

Recommend this journal