Gas chromatographic analysis of sodium valproate in plasma and urine after air assisted liquid-liquid microextraction


1 Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
2 Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
3 Lung and Tuberculosis Diseases Research Center, Tabriz University of Medical Science, Tabriz, Iran
4 Neurology Department, Aalinasab Hospital, Tabriz, Iran
5 Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences; Kimia Idea Pardaz Azarbayjan (KIPA) Science Based Company, Tabriz University of Medical Sciences, Tabriz, Iran

Correspondence Address:
Abolghasem Jouyban
Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences; Kimia Idea Pardaz Azarbayjan (KIPA) Science Based Company, Tabriz University of Medical Sciences, Tabriz
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

Rapid, highly efficient, and reliable liquid–liquid microextraction (LLME) methods followed by gas chromatography-flame ionization detection were developed for the extraction, preconcentration, and determination of valproate in human plasma and urine samples. Proteins of plasma sample are precipitated by adding methanol and urine sample was diluted prior to performing the microextraction procedures. Fine organic solvent droplets were formed by repeated suction and injection of the mixture of sample solution and extraction solvent into a test tube with a glass syringe. After extraction, phase separation was performed by centrifuging and the enriched analytes in the sedimented organic phase were determined by the separation system. The main factors influencing the extraction efficiency including extraction solvent type and volume, salt addition, pH, and extraction times are investigated. Under the optimized conditions, the proposed method showed good precision (relative standard deviation less than 8%). Limits of detection and lower limits of quantification for valproate were obtained in the ranges of 0.05.0.22 and 0.1.0.5μg mL-1, respectively. The linear ranges were 0.5–500 and 0.1–200 μg mL-1in plasma and urine, respectively (r2 ≥ 0.9995). The relative recoveries varied from 98–102 % and 93-100 %, respectively for plasma and urine samples. The mean relative standard deviations for intra-assay and inter-assay precisions were 3.4 % and 6.0 %, respectively. Preconcentration factors were in the range of 7-44. Good recoveries (55–86%) were obtained for the spiked samples. The proposed method was successfully used to analyze plasma and urine samples of epileptic receiving sodium valproate.


[PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed79    
    Printed9    
    Emailed0    
    PDF Downloaded49    
    Comments [Add]    

Recommend this journal